APPLICATION
These cables are suitable for control purpose or measuring circuits, in generating stations, sub-stations, industrial installations etc. as well as for railway signalling. The can be installed indoors or outdoors, in air or in cable ducts.
Type YWY/YFY
Armoured 1.5 and 2.5 sq.mm copper conductors up to 61 cores

APPLICATION
These cables are suitable for control purposes or measuring circuits in generating stations, sub-stations, industrial installations etc., as well as for railway signalling. On account for armouring, the cables can withstand rough installations and operation conditions and tensile stresses. These can be laid in water or buried direct in the ground, even on steep slopes. They can also be installed indoors or outdoors, in air or in cable ducts.
Back To Top
TROPODUR POWER CABLES 1100 V AS PER IS:1554 (PART I)-1988
Following cables for special applications are also available on enquity:-
Type AYY
Unarmoured Single-core with Aluminium conductors up to 1000 sq.mm.
APPLICATION
Light weight and small permissible bending radii makes single core TROPODUR Cables very easy to install. These cables are therefore particularly useful in power stations and sub-stations where a comparatively large number of cables in short lengths are to be used.
TROPODUR POWER CABLES 1100 V AS PER IS:1554 (PART I)-1988
Type AYY
Unarmoured Multi-core cables with Aluminium conductors up to 630 sq.mm.

APPLICATION
These power cables are suitable for use in generating stations, sub-stations, house service connections, street lighting, industrial installations, building wiring etc. They can be installed indoors or outdoors, in air or in cable ducts.
Type AYWY/AYFY
Armoured Multi-core cables with Aluminium conductors upto 500 sq.mm.
APPLICATION
These power cables are suitable for use in generating stations, sub-stations, distribution systems, house service connections, street lighting, industrial installations etc. On account of the armouring, the cables can withstand rough installation and operating conditions and tensile stresses, and can be laid in water or buried direct in the ground, even on steep slopes. They can also be installed indoors and outdoors, in air or in cable ducts.
Back To Top
TROPODUR POWER CABLES 1.9/3.3 kV* to 6.35/11 kV. AS PER IS:1554 (PART 2) - 1988
Type AYFY 3.8/6.6 kV (E)
Armoured Multi-core cables with Aluminium conductors up to 500 sq.mm.

*1.9/3.3 kV cables can be used on earthed or unearthed system.
APPLICATION
These cables can be used both indoors and outdoors, and can be directly laid in the ground or under water. These are suitable for power stations, switching stations, industrial plants and as feeders in electricity supply undertakings.
Type AYCEFY 11 kV (E)
Armoured Screened Multi-core cables with Aluminium conductors up to 500 sq.mm. *

APPLICATION
11 kV TROPODUR Cables are suitable for all types of industrial applications and particularly for hydro and thermal power stations and sub-stations. They are ideally suited for chemical and fertiliser industries on account of their better corrosion resistance or in heavy industries where severe load fluctuations occur and for systems where there are frequent over voltages.
Cables of 6.35/11 kV grade (Earthed system) can be used on 6.6/6.6 kV (Unearthed system) also.
Back To Top
TROPODUR MINING CABLES 1100 V AS PER IS: 1554 (PART I)-1988 AND 1.9/3.3 kV; 3.8/6.6 kV (E) AND 6.35/11 kV; AS PER IS: 1554 (PART 2) - 1988.
Type YFFGbY
Armoured Multi-core cables, with Copper conductors up to 500 sq.mm.

APPLICATION
TROPRODUR mining
cables are light in weight, and hence easier to
handle and install. It is provided with an armour
consisting of double layer of formed galvanised
steel wire which affords complete protection from
falling rocks, wagon tipping or any other mechanical
impact, and makes the cables strong enough to
withstand tensile force many times its own weight
especially when used as a shaft cable. Besides,
the incorporation of a counter - helix over the
top armour layer prevents bird caging. In addition,
to ensure an adequate path for earth fault currents,
the armour resistance is so designed that it never
exceeds that of the main conductor by more than
33%. All the above features make TROPODUR mining
cables ideally suited for use in all types of
mines.
FLAME RETARDANT LOW SMOKE PVC CABLES (FRLS)
Until recently,
flame retardance was never a major consideration
when choosing a cable. However, in the recent
past, the growing awareness of hazards due to
fire incidence in power plants, high rise buildings,
cable galleries etc., has resulted in the development
of FRLS Cables. As compared to normal TROPODUR
cables, TROPODUR (FRLS) cables offer improved
performance characteristics in respect of the
following:
1. Flame Retardance
2. Low Smoke Emission
3. Low Acid Gas Emission
In order to meet the above, special material is used for the outer sheath. The design, construction and testing of CCI's TROPODUR (FRLS) cables is as per IS: 1554 Part I and II.
Over and above
the standard tests, CCI subjects FRLS cables and
its components to a series of special tests to
fulfil the need of the improved fire performance
characteristics.
| Properties
& Test methods |
Guaranteed
Values |
| 1. Physical
Testing |
|
| 2. Smoke Density
Rating as per ASTM D-2843-77 |
60 % (max) |
| 3. Oxygen
Index Tests as per ASTM D-2863-77 |
29 (min) |
| 4. Temp Index
Tests adapted to ASTM D-2863-77 |
250 °
C (min) |
| 5. Acid Gas
Generation as per IEC-754-1 |
20 % (max) |
Apart from these tests on materials used on cables, following tests on finished cables are carried out:
- Test on electrical
cables under the conditions as per IEC 332-1
- Flammability
testing - Chimney test for Class F3 as per Swedish
Standards SS 424 1475
- Flame Tests
as per IEEE Standard 383, 1974.
Back To Top
APPLICATIONS:
FRLS cables are
ideal for use in high rise buildings, data processing
centres, hospitals, theatres, hotels, schools,
warehouses, industrial complexes, power stations,
underground railways, oil platforms and areas
where safety of personnel or protection of equipment
is necessary.

TROPODUR PVC
MINING CABLES
Mining Cables of
1.1 kV, 3.3 kV to 11 kV grade are also manufactured
as per IS:1554 with copper conductors. These cables
have been approved by the Director General of
Mines Safety for installation in mines.
GENERAL DESCRIPTION
CABLE TYPE YWWGbY
1.1 kV, 1.9/3.3 kV (E) & 3.8/6.6 kV (E) GRADES:
Stranded sector
shaped (sm) plain (untinned) annealed copper conductor,
PVC insulated, cores laid up together, provided
with common covering of plastic tape wrapping,
provided with double round wire armouring consisting
of galvanised round steel wires plus tinned round
copper wires wherever necessary (with separator
tape in between the two layers of armouring),
provided with steel tape counter helix (Gb) over
the armouring and PVC outer sheathed cables.
CABLE TYPE
YCEWWGbY 6.35/11 kV (E) GRADE:
Compact circulars
stranded (rm/v) plain (untinned) annealed copper
conductor screening of extruded semi-conducting
compound, PVC insulated, provided with insulation
screening over individual cores consisting of
lapped semi-conducting tape followed by copper
tape, cores laid up together with interstices
suitably filled with non-hygroscopic fillers,
provided with common covering of plastic tape
wrapping, with double round wire armouring consisting
of galvanized round steel wires plus tinned round
copper wires wherever necessary (with a separator
tape in between the two layers of armouring),
provided with steel tape counter helix (Gb) over
the armouring and PVC outer sheathed cables.
0.65/1.1 kV grade
PVC Mining Cables shall be as per IS:1554 (Part
I) 1988.
1.9/3.3 kV (E)
& 6.35/11 kV (E) grade PVC Mining Cables shall
be as per 1554 (Part II) 1988.
RESISTANCE OF
ARMOUR
In case of cables
for use in mines, the resistance of armour shall
not exceed that of conductor as specified in IS:8130
- 1984 by more than 33 per cent. To satisfy this,
substitution of galvanised round/formed* wires
in the armour by required number of tinned copper
wires/strips is permissible.
*Formed wires
were earlier known as 'flat wire (strip).'
Cables with the
following alternatives are also available on special
enquiries.
a) Common covering
of Extruded PVC inner sheath
b) Double Steel
Formed Wire (FF) Armouring
SPECIAL TYPES NOT
COVERED ABOVE CAN ALSO BE MANUFACTURED AGAINST
SPECIFIC ORDER. FOR EXAMPLE: HIGH TENSION CABLES
FOR AIRPORT LIGHTING PUR-POSES, PVC INSULATED
LEAD SHEATHED CABLES FOR HIGHLY CORROSIVE CONDITIONS,
SCREENED SIGNALLING CABLES, CABLES FOR LOW TEMPERATURE
ETC. FURTHER, TROPODUR CABLES TO VARIOUS FOREIGN
SPECIFICATIONS e.g. VDE, BS, ETC. HAVE BEEN MANUFACTURED
AND EXPORTED BY US ALL OVER THE WORLD.
Back To Top
|